NDT Technology

NDT Technology

Experimental and numerical investigation of heat exchanger tubes based on magnetic flux leakage method

Document Type : Original Article

Authors
Engineering Department, Shahid Rajaee Teacher Training University, Tehran, Iran
Abstract
One of the most widely used sectors in the industry is energy, which has been given many devices with the advancement of science and its emergence in the industry. In the discussion of energy, exchange is very important, the equipment used for this purpose is heat exchangers, and the heart of the heat exchanger is its tubes, which are responsible for this important. Due to high operating temperatures and proximity to the fluid, heat exchanger tubes become corroded or have various other defects over time and must be inspected periodically. One of the non-destructive inspection methods is magnetic flux leakage, which is based on magnetic testing, which is much less expensive than other methods due to the widespread use of ferromagnetic tubes in exchangers. According to research, an exchanger that is widely used in the industry has similar specifications to the heat exchangers of Pakman Company, a 3-pass horizontal steam boiler, model PSBHN-3500, ferromagnetic, with a small diameter and thick wall. Specifically, the tubes in question have an outer diameter of 50 mm and a wall thickness of 3 mm, seamless fire-resistant steel Mn417, which poses a challenge to other non-destructive testing methods. Given the conditions of the heat exchanger tubes, including the need to access both sides, the fastest and least expensive option for identifying corrosion defects is to use the magnetic flux leakage method. In this thesis, a simulation based on studies has been carried out first, then, according to the simulation results, a real device has been built and experimental tests have also been conducted. The result of these measures has been the detection of groove and hole defects with very low depth percentages on the control tube. With increasing the current applied to the electromagnetic generator, the signal voltage received from the sensor has increased, and with increasing the air gap of the sensor, the received voltage has decreased, and with increasing the air gap between the yoke legs and the surface of the inspected part, the peak value has decreased.
Keywords
Subjects

[1] Lee, J. Y., et al. (2000). HIERARCHICAL RULE BASED CLASSIFICATION OF MFL SIGNALS OBTAINED FROM NATURAL GAS PIPELINE INSPECTION. In Proceedings of the IEEE-INNS-ENNS International Joint Conference on Neural Networks (IJCNN 2000): Neural Computing: New Challenges and Perspectives for the New Millennium.
[2] Gotoh, Y., & Takahashi, N. (2006). 3D FEM ANALYSIS OF ELECTROMAGNETIC INSPECTION OF OUTER SIDE DEFECTS ON STEEL TUBE USING INNER COIL. In Proceedings of the 12th Biennial IEEE Conference on Electromagnetic Field Computation.
[3] Hua, G., et al. (2009). IMPROVING SNR OF MFL SIGNAL IN FLAW DETECTION OF COAL MINE WIRE ROPES. In Proceedings of the 2nd International Congress on Image and Signal Processing.
[4] Mao, B., et al. (2014). SIGNAL PROCESSING AND DEFECT ANALYSIS OF PIPELINE INSPECTION APPLYING MAGNETIC FLUX LEAKAGE METHODS. Intelligent Service Robotics, 7(4), 203–209.
[5] Peng, L., et al. (2018). A LIFT-OFF REVISION METHOD FOR MAGNETIC FLUX LEAKAGE MEASUREMENT SIGNAL. In Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2018).
[6] Lee, H., et al. (2019). MAGNETIC FLUX LEAKAGE MEASUREMENT SYSTEM FOR NONDESTRUCTIVE TESTING OF WATER-COOLED WALL. In Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2019).
[7] Trevino, D. A., Ghorbel, F. H., & Dutta, S. M. (2020). MAGNETO-OPTICAL AND HALL EFFECT MAGNETIC-FLUX LEAKAGE SENSING: A VALIDATION STUDY. IEEE Transactions on Magnetics, 56(3), 1–9.
[8] Hayashi, M., et al. (2021). IMAGING OF DEFECT SIGNAL OF REINFORCING STEEL BAR AT HIGH LIFT-OFF USING A MAGNETIC SENSOR ARRAY BY UNSATURATED AC MAGNETIC FLUX LEAKAGE TESTING. IEEE Transactions on Magnetics, 57(2), 1–4.
[9] Lu, J., et al. (2022). STUDY ON MAGNETIC FLUX LEAKAGE DETECTION OF BROKEN CABLE WIRE UNDER ROBOT SPIRAL CLIMBING. In Proceedings of the 41st Chinese Control Conference (CCC 2022).
[10] Ji, H., et al. (2023). RESEARCH ON STRUCTURE AND KEY PARAMETER MODELING OF EXCITATION DEVICE FOR MAGNETIC FLUX LEAKAGE DETECTION OF U-SHAPED HANGING RING. In Proceedings of the 7th International Conference on Electrical, Mechanical and Computer Engineering (ICEMCE 2023).
[11] Wang, Z., et al. (2024). APPLICATION AND DEVELOPMENT OF OIL PIPELINE MAGNETIC FLUX LEAKAGE DETECTION BASED ON MACHINE LEARNING ALGORITHM. In Proceedings of the 6th International Conference on Intelligent Control, Measurement and Signal Processing (ICMSP 2024).
[12] Qu, F., et al. (2025). DESIGN AND PERFORMANCE STUDY OF A MAGNETIC FLUX LEAKAGE PIG FOR SUBSEA PIPELINE DEFECT DETECTION. Journal of Marine Science and Engineering, 13(8), 1462.

  • Receive Date 17 November 2025
  • Revise Date 10 February 2026
  • Accept Date 19 February 2026