Experimental investigation of fluid leakage in pipes by signal processing of acoustic emission signals

Document Type : Original Article

Authors
Department of Mechanical Engineering, Tafresh University, Tafresh
Abstract
The integrity of piping systems is of critical importance across many industries due to the transportation of a wide range of fluids. The occurrence of leaks can disrupt operations, compromise safety, and significantly increase maintenance costs. In this study, the Acoustic Emission (AE) technique was employed as a non destructive, defect sensitive, and continuously monitorable approach to investigate leak behavior .A laboratory scale experimental setup was developed using pressurized water flowing through galvanized steel pipes to evaluate the acoustic characteristics of leakage under controlled conditions. Key parameters such as fluid pressure, leak orifice diameter, and pipe diameter were considered as independent variables. Acoustic Emission waveforms were collected and recorded using sensors installed at predetermined distances along the pipeline .Following noise reduction and the application of an appropriate band pass filter matched to the sensor bandwidth, time domain, statistical, and frequency domain features(ncluding amplitude, event counts, signal rise time, and signal energy)were extracted. These features enabled the discrimination of leak related acoustic signatures from background disturbances such as flow turbulence and mechanical vibrations .Graphical analyses conducted under six experimental conditions demonstrated that fluid pressure, pipe diameter, and leak orifice diameter systematically influence the acoustic response. Specifically, increasing the internal pressure or enlarging the leak aperture led to higher signal amplitudes and event rates. Furthermore, pipe diameter played a significant role in wave propagation characteristics and attenuation behavior .Overall, the findings validate Acoustic Emission as a rapid and reliable non destructive technique for structural health monitoring of pipelines and early leak detection. The integrated workflow combining feature based detection with sensitivity analysis of key physical parameters provides a practical foundation for real time (online) monitoring. The results further indicate that proper calibration with respect to pipe geometry and fluid properties, along with integration of AE systems into inspection and condition monitoring programs, is essential for reducing testing time and operational risk.
Keywords
Subjects

[1] F. Saleem, Z. Ahmad, M. F. Siddique, M. Umar, and J.-M. Kim, "Acoustic Emission-Based pipeline leak detection and size identification using a customized One-Dimensional densenet," Sensors, vol. 25, no. 4, p. 1112, 2025.
[2] R. M. Baptista and C. H. Wildhagen Moura, "Leak Detection Systems for Multiphase Flow: Moving Forward," in International Pipeline Conference, 2002, vol. 36207, pp. 1067-1074.
[3] A. Zagretdinov, S. Ziganshin, E. Izmailova, Y. Vankov, I. Klyukin, and R. Alexandrov, "Detection of Pipeline Leaks Using Fractal Analysis of Acoustic Signals," Fractal and Fractional, vol. 8, no. 4, p. 213, 2024.
[4] T. F. DROUILLARD, "A history of acoustic emission," Journal of acoustic emission, vol. 14, no. 1, pp. 1-34, 1996.
[5] Practical Acoustic Emission Testing. Tokyo: Springer Tokyo (in English), 2016.
[6] M. Ahadi and M. S. Bakhtiar, "Leak detection in water-filled plastic pipes through the application of tuned wavelet transforms to acoustic emission signals," Applied Acoustics, vol. 71, no. 7, pp. 634-639, 2010.
[7] D. Ozevin and J. Harding, "Novel leak localization in pressurized pipeline networks using acoustic emission and geometric connectivity," International Journal of Pressure Vessels and Piping, vol. 92, pp. 63-69, 2012.
[8] A. Mostafapour and S. Davoudi, "Analysis of leakage in high pressure pipe using acoustic emission method," Applied Acoustics, vol. 74, no. 3, pp. 335-342, 2013.
[9] J. Butterfield, A. Krynkin, R. Collins, and S. Beck, "Experimental investigation into vibro-acoustic emission signal processing techniques to quantify leak flow rate in plastic water distribution pipes," Applied Acoustics, vol. 119, pp. 146-155, 2017.
[10] S. Pan, Z. Xu, D. Li, and D. Lu, "Research on detection and location of fluid-filled pipeline leakage based on acoustic emission technology," Sensors, vol. 18, no. 11, p. 3628, 2018.
[11] T. B. Quy and J.-M. Kim, "Crack detection and localization in a fluid pipeline based on acoustic emission signals," Mechanical Systems and Signal Processing, vol. 150, p. 107254, 2021.
[12] A. Fares, I. Tijani, Z. Rui, and T. Zayed, "Leak detection in real water distribution networks based on acoustic emission and machine learning," Environmental Technology, vol. 44, no. 25, pp. 3850-3866, 2023.
[13] N. Ullah, Z. Ahmed, and J.-M. Kim, "Pipeline leakage detection using acoustic emission and machine learning algorithms," Sensors, vol. 23, no. 6, p. 3226, 2023.
[14] J. Cui, M. Zhang, X. Qu, J. Zhang, and L. Chen, "An Improved Identification Method of Pipeline Leak Using Acoustic Emission Signal," Journal of Marine Science and Engineering, vol. 12, no. 4, p. 625, 2024.
[15] A. Ali, W. Xinhua, and I. Razzaq, "Optimizing acoustic signal processing for localization of precise pipeline leakage using acoustic signal decomposition and wavelet analysis," Digital Signal Processing, vol. 157, p. 104890, 2025.
[16] J. Cui and J. Du, "Investigation into acoustic emission-based methodology for precise localization of pipeline leakage sources," Measurement, vol. 250, p. 117194, 2025.
 

  • Receive Date 16 September 2025
  • Revise Date 15 July 2026
  • Accept Date 04 October 2026